  1. Partitions cannot be mounted.
  2. To mount partitions use Mounter
  3. or reboot system.
  4.  
  5. This name is too long.  Use a name shorter than 27 characters.
  6.  
  7. Since the driver could not be installed into your system now, your partitions cannot be initialized now.  You may initialize them when you reboot. 
  8.  
  9. The driver has been written to the disk.  However, there is not enough room in the system heap for your driver to be installed into your system now.  The driver will be installed into your system when you reboot.   
  10.  
  11. There are no HFS partitions on the disk for the driver.  Therefore, it cannot be installed in the system.
  12.  
  13. There is not enough free memory to read and write to the disk. 
  14.  
  15. The buffer was successfully written to the disk.
  16.  
  17. Too many defects!  The disk is bad or some other error is occurring.
  18.  
  19. Sorry, not all of the volumes on the disk could be unmounted.  Therefore, the driver can not be installed into the system.  Do you want to write the driver to the disk anyway?
  20.  
  21. There is a file open on this partition.  Therefore, it can not be removed.
  22.  
  23. There is a maximum of 15 characters for a password.
  24.  
  25. Sense error during format command. 
  26. The system has returned an error relating to the defect list header.  Some drives expect an alternate form of the defect list header.  The alternate form will be used for a second attempt.
  27.  
  28. Phase error during format command. 
  29. The system has returned an error.  Some drives expect an alternate form of the format command.  The alternate form will be used for a second attempt.
  30.  
  31. Incompatable Partition Map.  A valid Partition Map must be installed before updating the driver.
  32.  
  33. Incompatable Partition Map.  Custom Install will not allow modification of the existing partition map.
  34.  
  35. In order to allow modification of the current partition map, the driver on the disk needs to be updated.  Is this OK?
  36.  
  37. Writing the partition map without performing a low level format or initialization of the new partitions may cause unpredictable results.  See README file for more information.
  38.  
  39. Creating a partition this size will also create a very small free block partition.  This free space will be unusable unless another partition is removed.  Do you want to do this?
  40.  
  41. Park Disk(s) will park all available SCSI disk(s) and shut down your computer.  Do you want to proceed?
  42.  
  43. All existing data within the partition(s) that were removed from the Partition Map will be DESTROYED. Do you want to proceed?
  44.  
  45. Reassigning this block will destroy the data that is on this block.  Is this OK?
  46.  
  47. The block could not be reassigned.
  48.  
  49. No new defects were found on the disk. 
  50.  
  51. The block was read successfully.  The data is saved in a buffer that can be written back to the disk.
  52.  
  53. The block number that is about to be reassigned is not on the defect list. Is this OK?
  54.  
  55. Sorry, this block could not be read from the disk.  Reassigning this block will destroy the data on this block.  Is this OK?
  56.  
  57. Block was successfully reassigned. 
  58.  
  59. Sorry, this block could not be read from the disk.
  60.  
  61. This free block is too small to make into a partition.  Remove a bordering partition to enlarge it.
  62.  
  63. Unable to unmount volume; a file on this disk is open.  Use Blue Disc Manager for installation. See README for more information.
  64.  
  65. The maximum number of partitions has been reached.  This free space will be REPLACED with a new Partition.
  66.  
  67. Invalid decimal number entered.
  68.  
  69. This disk does not allow any other interleave.
  70.  
  71. Warning, this SCSI ID is already taken.  Make sure that two devices do not have the same SCSI ID when you reboot.
  72.  
  73. When you reset your computer, the disk will use its hardware setting for its SCSI ID.
  74.  
  75. When your computer is reset, the disk will have this new SCSI ID.
  76.  
  77. This disk does not support software selectable SCSI ID's.
  78.  